IFM SD9000 Compressed air meter

IFM SD9000

Kami menjual IFM SD9000 di Indonesia barang-barang kami semua berkualitas Original dengan harga yang bersaing dengan Perusahaan lain

IFM SD9000 Compressed air meter Feature :

  • Precise measurement of flow, consumption and medium temperature
  • High accuracy, repeatability and measurement dynamics
  • For detecting compressed air in industrial use
  • With switching output, analogue output and pulse output
  • Clearly visible 4-digit LED display

IFM SD9000 Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Process connectionthreaded connection R 1 1/2 DN40
Temperature monitoring
Measuring range [°C]0…60
Application
Applicationfor industrial applications
Mediacompressed air
Note on media
air quality ISO 8573-1
class 141
class 344
Medium temperature [°C]0…60
Pressure rating [bar]16
Pressure rating [Mpa]1.6

 Electrical data

Operating voltage [V]18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]< 110
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]1
IFM SD9000 Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250; (per output)
Number of analogue outputs1
Analogue current output [mA]4…20; (scalable)
Max. load [Ω]500
Pulse outputconsumed quantity meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

IFM SD9000 Measuring/setting range

Measuring range
20…6835 l/min0.3…95.3 m/s1.5…410 m³/h
Display range
0…8200 l/min0…114.4 m/s0…492 m³/h
Set point SP
55…6835 l/min0.8…95.3 m/s3.5…410 m³/h
Reset point rP
20…6800 l/min0.3…94.8 m/s1.5…408 m³/h
Analogue start point ASP
0…5125 l/min0…71.5 m/s0…307.5 m³/h
Analogue end point AEP
1710…6835 l/min23.8…95.3 m/s102.5…410 m³/h
In steps of
5 l/min0.1 m/s0.5 m³/h
Volumetric flow quantity monitoring
Pulse value0.005…4 000 000 m³
In steps of0.001 m³
Pulse length [s]0,018…2
IFM SD9000 Temperature monitoring
Measuring range [°C]0…60
Display range [°C]-12…72
Accuracy / deviations
IFM SD9000 Flow monitoring
Repeatability [% of the measured value]± 1,5
Accuracy (in the measuring range)± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 / ; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN40)
Temperature monitoring
Accuracy [K]± 2; (medium flow in the limit area of the flow measurement range)
IFM SD9000 Response times
Flow monitoring
Response time [s]0.1; (dAP = 0)
Damping for the switching output dAP in steps [s]0 – 0,2 – 0,4 – 0,6 – 0,8 – 1
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
IO-Link device ID269 d / 00 01 0D h
Profilesno profile
SIO modeyes
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time [ms]4.1

Operating conditions

Ambient temperature [°C]0…60
Storage temperature [°C]-20…85
Max. relative air humidity [%]90
ProtectionIP 65
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Vibration resistance
DIN EN 68000-2-65 g (55…2000 Hz)
MTTF [years]227
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request
IFM SD9000 Mechanical data
Weight [g]4004
MaterialsPBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; aluminium powder-coated
Materials (wetted parts)stainless steel (1.4301 / 304); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminium
Process connectionthreaded connection R 1 1/2 DN40

IFM SD9000 Displays / operating elements

Display
Display unit5 x LED, green (Nl/min, Nm³/h, Nm/s, Nm³, °C)
function display1 x LED, green
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
For information about installation and operation please see the operating instructions.
Pack quantity1 pcs.
Electrical connection
Connection

Type IFM SD9000 lainnya

SD8500
SD2500
SD9500
SD5500
SD6500
SD8000
SD6000
SD0523
SD6050
SD2000
SD8600
SD6600
SD5600
SD6100
SD5000
SD9000
SD5100
SD8100
SD6101
SDG070
SDG207
SD6001
SDG107
SDG087
SD8001
SDG157
SDG152
SDG082
SDG200
SDG201
SDG080
SDG100
SDG150
SD2001
SDG102
SD1540
SD2501
SD8501
SD6601
SD8601
SD5800
SD6800

Produk IFM SD9000 yang kami jual adalah barang baru dan bergaransi resmi, silahkan Hubungi Tim marketing kami yang siap membantu untuk info lebih lanjut dan juga untuk mengetahui info harga dan stok dari IFM SD9000 atau produk kami lainnya.

Datasheet Katalog IFM SD9000